<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ideal Scientific</title>
	<atom:link href="http://www.idealscientific.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.idealscientific.com</link>
	<description>Ideal Scientific</description>
	<lastBuildDate>Tue, 22 May 2012 20:41:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.2</generator>
		<item>
		<title>Triple-Display Digital Thermometers &#8211; Certified</title>
		<link>http://www.idealscientific.com/2488/triple-display-digital-thermometers-certified/</link>
		<comments>http://www.idealscientific.com/2488/triple-display-digital-thermometers-certified/#comments</comments>
		<pubDate>Tue, 22 May 2012 20:40:33 +0000</pubDate>
		<dc:creator>brenda</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2488</guid>
		<description><![CDATA[For:  Freezers, Refrigerators, Incubators, Water Baths and Block Heaters. The Triple-Display Digital Thermometer simultaneously shows the current, minimum, and maximum &#8230; <a class="read-more" href="http://www.idealscientific.com/2488/triple-display-digital-thermometers-certified/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>For:  Freezers, Refrigerators, Incubators, Water Baths and Block Heaters.</p>
<p><span style="color: #333333;">The Triple-Display Digital Thermometer simultaneously shows the current, minimum, and maximum temperatures and updates continuously. An audible alarm will sound when the temperatures rises above or goes below the set temperatures. The minimum/maximum feature monitors critical temperature for any period of time, such as overnight or weekend. Reset buttons on front panel.</span><span style="color: #333333; font-family: Verdana;"> </span></p>
<p><span style="color: #333333;">Each thermometer is certified and traceable to N.I.S.T. and is supplied with a certificate with one critical temperature value calibrated with the reported results. Each thermometer is serialized.</span></p>
<p><span style="color: #333333;">The thermometer probe is housed in an unbreakable plastic bottle or vial filled with a buffering media which maintains the thermometer reading when the instrument door is opened.<span style="font-family: Verdana;">  </span>The thermometer and the bottle housing the probe have dual magnets allowing attachment to doors or walls of the instrument. </span><span style="color: #333333;">Other features include a flip-open stand and wall mounting key hole.</span></p>
<ul>
<li>Triple temperature display – Current, Minimum, &amp; Maximum temperatures</li>
<li>Audible alarm</li>
<li>N.I.S.T. Traceable</li>
<li>Each thermometer individually serialized</li>
<li>Certificate provided with one critical temperature certified</li>
<li>Accuracy +/- 0.5ºC, Resolution 0.1ºC &amp; F</li>
<li>Temperature probe housed in plastic bottle filled with a liquid medium</li>
<li>Switchable between ºC and ºF</li>
<li>Supplied with AAA alkaline battery</li>
<li>Thermometer can be used to monitor ambient temperatures</li>
<li>Display size: 79mm x 66mm</li>
<li>Thermometer size: 98mm x 110mm x 21mm</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="128"><strong><span style="color: #000000;">Item No.</span></strong></td>
<td valign="top" width="128"><strong><span style="color: #000000;">Application</span></strong></td>
<td valign="top" width="128"><strong><span style="color: #000000;">Temperature Range</span></strong></td>
<td valign="top" width="128"><strong><span style="color: #000000;">Bottle Media</span></strong></td>
<td valign="top" width="128"><strong><span style="color: #000000;">Certified Temperature</span></strong></td>
</tr>
<tr>
<td valign="top" width="128"><span style="color: #000000;">IS21355</span></td>
<td valign="top" width="128"><span style="color: #000000;">Freezer</span></td>
<td valign="top" width="128"><span style="color: #000000;">-50º to 70ºC</span></td>
<td valign="top" width="128"><span style="color: #000000;">50% Ethylene Glycol 30ml</span></td>
<td valign="top" width="128"><span style="color: #000000;">-20.0ºC</span></td>
</tr>
<tr>
<td valign="top" width="128"><span style="color: #000000;">IS21356</span></td>
<td valign="top" width="128"><span style="color: #000000;">Refrigerator</span></td>
<td valign="top" width="128"><span style="color: #000000;">-50º to 70ºC</span></td>
<td valign="top" width="128"><span style="color: #000000;">50% Ethylene Glycol 30ml</span></td>
<td valign="top" width="128"><span style="color: #000000;">+4.0ºC</span></td>
</tr>
<tr>
<td valign="top" width="128"><span style="color: #000000;">IS21357</span></td>
<td valign="top" width="128"><span style="color: #000000;">Incubator</span></td>
<td valign="top" width="128"><span style="color: #000000;">-50º to 70ºC</span></td>
<td valign="top" width="128"><span style="color: #000000;">50% Ethylene Glycol 30ml</span></td>
<td valign="top" width="128"><span style="color: #000000;">+37.0ºC</span></td>
</tr>
<tr>
<td valign="top" width="128"><span style="color: #000000;">IS21358</span></td>
<td valign="top" width="128"><span style="color: #000000;">Water Bath</span></td>
<td valign="top" width="128"><span style="color: #000000;">-50º to 70ºC</span></td>
<td valign="top" width="128"><span style="color: #000000;">None</span></td>
<td valign="top" width="128"><span style="color: #000000;">+37.0ºC</span></td>
</tr>
<tr>
<td valign="top" width="128"><span style="color: #000000;">IS21359</span></td>
<td valign="top" width="128"><span style="color: #000000;">Block Heater</span></td>
<td valign="top" width="128"><span style="color: #000000;">-50º to 70ºC</span></td>
<td valign="top" width="128"><span style="color: #000000;">Mineral Oil 1ml</span></td>
<td valign="top" width="128"><span style="color: #000000;">+37.0ºC</span></td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2488/triple-display-digital-thermometers-certified/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ovation® BioNatural Multichannel Pipettes</title>
		<link>http://www.idealscientific.com/2473/ovation-bionatural-multichannel-pipettes/</link>
		<comments>http://www.idealscientific.com/2473/ovation-bionatural-multichannel-pipettes/#comments</comments>
		<pubDate>Tue, 22 May 2012 16:57:11 +0000</pubDate>
		<dc:creator>brenda</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2473</guid>
		<description><![CDATA[The Ovation® Multichannel Pipette has an ergonomically-correct, comfort-driven design with electronic functions to meet the complex demands of repetitive procedures.  &#8230; <a class="read-more" href="http://www.idealscientific.com/2473/ovation-bionatural-multichannel-pipettes/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>The Ovation® Multichannel Pipette has an ergonomically-correct, comfort-driven design with electronic functions to meet the complex demands of repetitive procedures.  Straightforward, simple programming coupled with reliable, consistent accuracy and precision ensures the integrity of your work is always achieved with uncompromised confidence.</p>
<p><strong>Ergonomically-correct pipetting = Less effort, more comfort.  </strong>Ovation pipettes are designed for ergonomically-correct pipetting &#8211; it&#8217;s shape naturally follows the contours of the palm, and allows the task of pipetting to be performed with a neutral posture and minimal muscular movement.  Low hand and arm elevations ease stress in the shoulder and neck, and a stress-free wrist angle eliminates uncomfortable extension and radial deviation movements in the arm.  Force, velocity and exertion from repetition or duration have also been neutralized.  Pipetting is inherently a labour-intensive, repetitious task &#8211; but it doesn&#8217;t have to be fatiguing or painful.  That&#8217;s something you can change with Ovation - the <em>comfortable</em> choice.</p>
<ul>
<li><strong>Acquire every tip &#8211; EVERY TIME: </strong> Positive feedback indicates every tip is securely seated and sealed &#8211; no manual manipulations are needed</li>
<li><strong>Discard every tip &#8211; EVERY TIME:  </strong>An energy-release system uses the force captured during acquisition to simultaneously discard all tips &#8211; at the gentle push of a button</li>
<li><strong>Easy set-up and use of all functions:  </strong>Multiple Dispense, Pipette, Reverse Pipette, Mix and Serial Dilute operations are available at user-selectable settings</li>
<li><strong>Effortless push-button controls:  </strong>Select liquid handling functions with just a single keystroke, including recall of stored volume settings</li>
</ul>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="top" width="638"><span style="color: #000000;"><span style="color: #1c5fa9;"><strong>Volume Range 0.5 &#8211; 20</strong><strong>µl</strong></span><strong></strong></span></td>
</tr>
<tr>
<td rowspan="2" valign="top" width="319"><strong><span style="color: #000000;">Item No.</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;"><strong>8 Channel:</strong> IS20813, IS20814 (LH)</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;"><strong>12 Channel:</strong> IS20815, IS20816 (LH)</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Colour</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">Yellow</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Dispensing Increments</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">0.05µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Accuracy*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">±1.0% at 20µl, ±1.5% at 10µl, ±3.0% at 2µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Precision*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">0.40% at 20µl, 0.80% at 10µl, 1.80% at 2µl</span></td>
</tr>
</tbody>
</table>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="top" width="638"><span style="color: #000000;"><span style="color: #1c5fa9;"><strong>Volume Range 2 &#8211; 125</strong><strong>µl</strong></span><strong></strong></span></td>
</tr>
<tr>
<td rowspan="2" valign="top" width="319"><strong><span style="color: #000000;">Item No.</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;"><strong>8 Channel:</strong> IS20817, IS20818 (LH)</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;"><strong>12 Channel:</strong> IS20819, IS20820 (LH)</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Colour</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">Green</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Dispensing Increments</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">0.5µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Accuracy*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">±0.8% at 125µl, ±1.0% at 62.5µl, ±3.0% at 12.5µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Precision*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">0.25% at 125µl, 0.30% at 62.5µl, 1.25% at 12.5µl</span></td>
</tr>
</tbody>
</table>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="top" width="638"><span style="color: #000000;"><span style="color: #1c5fa9;"><strong>Volume Range 5 &#8211; 250</strong><strong>µl</strong></span><strong></strong></span></td>
</tr>
<tr>
<td rowspan="2" valign="top" width="319"><strong><span style="color: #000000;">Item No.</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;"><strong>8 Channel:</strong> IS20821, IS20822 (LH)</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;"><strong>12 Channel:</strong> IS20823, IS20824 (LH)</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Colour</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">Blue</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Dispensing Increments</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">1µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Accuracy*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">±0.8% at 250µl, ±1.0% at 125µl, ±2.5% at 25µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Precision*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">0.25% at 250µl, 0.40% at 125µl, 1.00% at 25µl</span></td>
</tr>
</tbody>
</table>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="top" width="638"><span style="color: #000000;"><span style="color: #1c5fa9;"><strong>Volume Range 25 &#8211; 850</strong><strong>µl</strong></span><strong></strong></span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Item No.</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;"><strong>12 Channel:</strong> IS20825, IS20826 (LH)</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Colour</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">Charcoal</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Dispensing Increments</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">5µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Accuracy*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">±1.0% at 850µl, ±1.25% at 425µl, ±3.5% at 85µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Precision*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">0.30% at 850µl, 0.40% at 425µl, 1.00% at 85µl</span></td>
</tr>
</tbody>
</table>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="top" width="638"><span style="color: #000000;"><span style="color: #1c5fa9;"><strong>Volume Range 25 &#8211; 1250</strong><strong>µl</strong></span><strong></strong></span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Item No.</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;"><strong>8 Channel:</strong> IS20827, IS20828 (LH)</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Colour</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">Purple</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Dispensing Increments</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">5µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Accuracy*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">±0.8% at 1250µl, ±1.0% at 625µl, ±3.5% at 125µl</span></td>
</tr>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Precision*</span></strong></td>
<td valign="top" width="319"><span style="color: #000000;">0.20% at 1250µl, 0.30% at 625µl, 0.80% at 125µl</span></td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2473/ovation-bionatural-multichannel-pipettes/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>TC-4000 Thermal Cycler</title>
		<link>http://www.idealscientific.com/2466/tc-4000-thermal-cycler/</link>
		<comments>http://www.idealscientific.com/2466/tc-4000-thermal-cycler/#comments</comments>
		<pubDate>Wed, 09 May 2012 20:02:37 +0000</pubDate>
		<dc:creator>brenda</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2466</guid>
		<description><![CDATA[The TC-4000 is one of the most affordable full sized thermal cyclers in the market, flexible for all your protocols &#8230; <a class="read-more" href="http://www.idealscientific.com/2466/tc-4000-thermal-cycler/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>The TC-4000 is one of the most affordable full sized thermal cyclers in the market, flexible for all your protocols and easy on your budget.</p>
<p><strong>High performance: </strong>High performance, high sample throughput model for maximum flexibility and economy and ideal for a larger number of parallel samples.</p>
<p><strong>Versatile block format: </strong>The truly user-friendly fully interchangeable block system allows blocks to be exchanged in a matter of seconds without the need for any tools (60 x 0.5mL, 96 x 0.2mL, 96-well fully skirted plates, 384-well or flat plate for <em>In-situ</em>).</p>
<p><strong>Flexible heated lid: </strong>Defined pressure, programmable heated lid (100°C to 115°C) to accommodate a variety of consumables.  The heated lid only comes on if the block is set above 35°C.</p>
<p><strong>Intuitive programming: </strong>4-line display with intuitive, simple-to-use software with alphanumeric programming, password protection, simple copy/edit functions and much more.</p>
<ul>
<li>Temperature range 4°C to 99°C</li>
<li>Excellent heating rate of 2.6°C/sec and block uniformity of ±0.3°C at 50°C ensures high reproducibility</li>
<li>8 Peltiers; using the innovative Quad Circuit Technology, the TC-4000 ensures unsurpassed control accuracy and temperature uniformity</li>
<li>The TC-4000 can be connected to a PC along with other Techne cyclers for high throughput applications using Gensoft software</li>
</ul>
<p><strong>Warranty:  </strong>Full 4-year warranty on cycler with blocks having a 4-year or 80,000 cycle warranty – whichever comes first.</p>
<table width="100%" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="258"><strong>Item No.</strong></td>
<td width="414"><strong>Description</strong></td>
</tr>
<tr>
<td width="258"><strong>IS18352</strong></td>
<td width="414">TC-4000 Thermal Cycler for 60 x 0.5ml microtubes, 115V/230V</td>
</tr>
<tr>
<td width="258"><strong>IS18353</strong></td>
<td width="414">TC-4000 Thermal Cycler for 96 x 0.2ml microtubes or 96-well plates, 115V/230V</td>
</tr>
<tr>
<td width="258"><strong>IS18354</strong></td>
<td width="414">TC-4000 Thermal Cycler for 96 x 0.2ml microtubes or 96-well fully skirted plates, 115V/230V</td>
</tr>
<tr>
<td width="258"><strong>IS18355</strong></td>
<td width="414">TC-4000 Thermal Cycler with flat plate for <span style="color: #000000;"><em><span style="font-family: Verdana;">In-situ</span></em>, 115V/230V</span></td>
</tr>
<tr>
<td width="258"><strong>IS18356</strong></td>
<td width="414">TC-4000 Thermal Cycler for 384-well plates, 115V/230V</td>
</tr>
<tr>
<td width="258"><strong>IS18357</strong></td>
<td width="414">TC-4000 Block for 60 x 0.5mL microtubes</td>
</tr>
<tr>
<td width="258"><strong>IS18358</strong></td>
<td width="414">TC-4000 Block for 96 x 0.2mL microtubes or 96-well plates</td>
</tr>
<tr>
<td width="258"><strong>IS18359</strong></td>
<td width="414">TC-4000 Block for 96 x 0.2mL microtubes or 96-well fully skirted plates</td>
</tr>
<tr>
<td width="258"><strong>IS18360</strong></td>
<td width="414">TC-4000 Block with flat plate for <em><span style="color: #000000;"><span style="font-family: Verdana;">In-situ</span></span></em></td>
</tr>
<tr>
<td width="258"><strong>IS18361</strong></td>
<td width="414">TC-4000 Block for 384-well plates</td>
</tr>
<tr>
<td colspan="2" width="672"></td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Block Formats</strong></td>
</tr>
<tr>
<td width="258">0.5mL block capacity</td>
<td width="414">60</td>
</tr>
<tr>
<td width="258">0.2mL block capacity</td>
<td width="414">96</td>
</tr>
<tr>
<td width="258">384-well</td>
<td width="414">Yes</td>
</tr>
<tr>
<td width="258"><em>In-situ</em></td>
<td width="414">Yes</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Block Temperature</strong></td>
</tr>
<tr>
<td width="258">Maximum Ramp Rate</td>
<td width="414">2.6°C/sec</td>
</tr>
<tr>
<td width="258">Block Uniformity at 50°C</td>
<td width="414">&lt;±0.3°C</td>
</tr>
<tr>
<td width="258">Temperature Range</td>
<td width="414">4°C to 99°C</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Heated Lid</strong></td>
</tr>
<tr>
<td width="258">Selectable Heated Lid Temperature</td>
<td width="414">100°C to 115°C</td>
</tr>
<tr>
<td width="258">Heated Lid – Enable/Disable</td>
<td width="414">Yes</td>
</tr>
<tr>
<td width="258">Over-temperature Cut-out</td>
<td width="414">Yes</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Programming</strong></td>
</tr>
<tr>
<td width="258">No. of Programs</td>
<td width="414">80</td>
</tr>
<tr>
<td width="258">Password Protection</td>
<td width="414">Yes</td>
</tr>
<tr>
<td width="258">Programming Display</td>
<td width="414">4-line alphanumeric</td>
</tr>
<tr>
<td width="258">Auto Restart on Power Failure</td>
<td width="414">Yes</td>
</tr>
<tr>
<td width="258">Dimensions (WxLxH)</td>
<td width="414">220 x 420 x 260mm (8.7 x 16.5 x 10.2&#8243;)</td>
</tr>
<tr>
<td width="258">Voltage</td>
<td width="414">115/230V 50-60Hz</td>
</tr>
<tr>
<td width="258">Power</td>
<td width="414">620W</td>
</tr>
<tr>
<td width="258">Shipping Weight</td>
<td width="414">13kg (28.6 lbs)</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2466/tc-4000-thermal-cycler/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>TC-3000X Thermal Cycler</title>
		<link>http://www.idealscientific.com/2463/tc-3000x-thermal-cycler/</link>
		<comments>http://www.idealscientific.com/2463/tc-3000x-thermal-cycler/#comments</comments>
		<pubDate>Wed, 09 May 2012 19:30:28 +0000</pubDate>
		<dc:creator>brenda</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2463</guid>
		<description><![CDATA[The TC-3000X personal cycler is based on the unrivalled and reliable TC-3000.  This model is ideal for those laboratories that &#8230; <a class="read-more" href="http://www.idealscientific.com/2463/tc-3000x-thermal-cycler/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>The TC-3000X personal cycler is based on the unrivalled and reliable TC-3000.  This model is ideal for those laboratories that need just that little bit more, with its expanded sample capacity to accommodate 48 x 0.2mL tubes or for convenience, a 48-well plate.</p>
<p><strong>Increased sample capacity: </strong>The footprint remains the same, only 561cm² but the capacity increases to 48 x 0.2mL or 30 x 0.5mL tubes.</p>
<p><strong>Adjustable heated lid: </strong>The heated lid can now be adjusted for use with all PCR tubes, strip tubes or 48-well plates sealed with sealing mats.</p>
<p><strong>Rapid heating rate: </strong>Utilizing the latest Peltier technology, the TC-3000X has a heating ramp rate of 3.3°C/sec and a 2.0°C/sec cooling rate.</p>
<p><strong>Fast-track programming: </strong>Modern intuitive programming and ready-to-go templates means creating even the most complicated protocols is simple.</p>
<p><strong>PC control &amp; networking: </strong>The TC-3000X can be linked together with other Techne cyclers; up to 32 cyclers can be networked to one computer.</p>
<p><strong>Warranty:  </strong>Full 4-year warranty on cycler with blocks having a 4-year or 80,000 cycle warranty – whichever comes first.</p>
<table width="100%" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="258"><strong>Item No.</strong></td>
<td width="414"><strong>Description</strong></td>
</tr>
<tr>
<td width="258"><strong>IS18344</strong></td>
<td width="414">TC-3000X Thermal Cycler for 48 x 0.2ml microtubes, 100V/115V/230V</td>
</tr>
<tr>
<td width="258"><strong>IS18345</strong></td>
<td width="414">TC-3000X Thermal Cycler for 30 x 0.5ml microtubes, 100V/115V/230V</td>
</tr>
<tr>
<td width="258"><strong>IS18346</strong></td>
<td width="414">TC-3000 Block for 48 x 0.2ml microtubes</td>
</tr>
<tr>
<td width="258"><strong>IS18347</strong></td>
<td width="414">TC-3000 Block for 30 x 0.5ml microtubes</td>
</tr>
<tr>
<td colspan="2" width="672"></td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Block Formats</strong></td>
</tr>
<tr>
<td width="258">0.5mL block capacity</td>
<td width="414">30</td>
</tr>
<tr>
<td width="258">0.2mL block capacity</td>
<td width="414">48</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Block Temperature</strong></td>
</tr>
<tr>
<td width="258">Maximum Ramp Rate</td>
<td width="414">3.3°C/sec</td>
</tr>
<tr>
<td width="258">Block Uniformity at 50°C</td>
<td width="414">±0.2°C</td>
</tr>
<tr>
<td width="258">Temperature Range</td>
<td width="414">4°C to 99°C</td>
</tr>
<tr>
<td width="258">Peltier Element/Block</td>
<td width="414">6</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Heated Lid</strong></td>
</tr>
<tr>
<td width="258">Selectable Heated Lid Temperature</td>
<td width="414">100°C to 115°C</td>
</tr>
<tr>
<td width="258">Heated Lid – Enable/Disable</td>
<td width="414">Yes</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Programming</strong></td>
</tr>
<tr>
<td width="258">No. of Programs</td>
<td width="414">80</td>
</tr>
<tr>
<td width="258">Programming Display</td>
<td width="414">4-line alphanumeric</td>
</tr>
<tr>
<td width="258">Auto Restart on Power Failure</td>
<td width="414">Yes</td>
</tr>
<tr>
<td width="258">Dimensions (WxLxH)</td>
<td width="414">170 x 330 x 190mm (6.7 x 13 x 7.5”)</td>
</tr>
<tr>
<td width="258">Voltage</td>
<td width="414">100/115/230V 50-60Hz</td>
</tr>
<tr>
<td width="258">Power</td>
<td width="414">230W</td>
</tr>
<tr>
<td width="258">Shipping Weight</td>
<td width="414">6 kg (13.2 lbs)</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2463/tc-3000x-thermal-cycler/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>TC-3000 Thermal Cycler</title>
		<link>http://www.idealscientific.com/2460/tc-3000-thermal-cycler/</link>
		<comments>http://www.idealscientific.com/2460/tc-3000-thermal-cycler/#comments</comments>
		<pubDate>Wed, 09 May 2012 19:17:52 +0000</pubDate>
		<dc:creator>brenda</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2460</guid>
		<description><![CDATA[The TC-3000 thermal cycler is unrivalled as the most reliable, low cost personal cycler.  Designed with research and teaching laboratories &#8230; <a class="read-more" href="http://www.idealscientific.com/2460/tc-3000-thermal-cycler/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>The TC-3000 thermal cycler is unrivalled as the most reliable, low cost personal cycler.  Designed with research and teaching laboratories in mind, the TC-3000 offers the ultimate in low cost solutions where ease of use is high on the priority list.</p>
<p><strong>Space saving small footprint: </strong>One of the world&#8217;s bestselling personal thermal cyclers, the TC-3000 is even economical on space.</p>
<p><strong>Rapid heating rate: </strong>Utilizing the latest Peltier technology the TC-3000 can heat at 3.6°C/sec and cool at 2.0°C/sec.</p>
<p><strong>Heated lid: </strong>The adjustable heated lid (100C to 115C), designed to reduce the risk of sample evaporation, can be enabled or disabled.  The heated lid only comes on if the block is set above 35°C.</p>
<p><strong>Fast-track programming: </strong>Modern intuitive programming and ready-to-go templates means creating even the most complicated protocols is simple.</p>
<p><strong>PC control &amp; networking: </strong>The TC-3000 can be linked together with any other Techne cyclers; up to 32 cyclers can be networked to one computer.</p>
<p><strong>Additional benefits</strong></p>
<ul>
<li>Temperature range 4°C to 99°C</li>
<li>Block uniformity of ±0.1°C at 50°C, ensuring optimal reproducibility</li>
<li>Password protection: protect your program against unwanted modifications</li>
<li>Portable dual voltage: has a variable voltage selector</li>
</ul>
<p><strong>Warranty: </strong> Full 4-year warranty on cycler with blocks having a 4-year or 80,000 cycle warranty – whichever comes first.</p>
<table width="100%" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="258"><strong>Item No.</strong></td>
<td width="414"><strong>Description</strong></td>
</tr>
<tr>
<td width="258"><strong>IS18340</strong></td>
<td width="414">TC-3000 Thermal Cycler for 25 x 0.2ml microtubes, 100V/115V/230V</td>
</tr>
<tr>
<td width="258"><strong>IS18341</strong></td>
<td width="414">TC-3000 Thermal Cycler for 20 x 0.5ml microtubes, 100V/115V/230V</td>
</tr>
<tr>
<td width="258"><strong>IS18343</strong></td>
<td width="414">TC-3000 Block for 25 x 0.2ml microtubes</td>
</tr>
<tr>
<td width="258"><strong>IS18342</strong></td>
<td width="414">TC-3000 Block for 20 x 0.5ml microtubes</td>
</tr>
<tr>
<td colspan="2" width="672"></td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Block Formats</strong></td>
</tr>
<tr>
<td width="258">0.5mL block capacity</td>
<td width="414">20</td>
</tr>
<tr>
<td width="258">0.2mL block capacity</td>
<td width="414">25</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Block Temperature</strong></td>
</tr>
<tr>
<td width="258">Maximum Ramp Rate</td>
<td width="414">3.6°C/sec</td>
</tr>
<tr>
<td width="258">Block Uniformity at 50°C</td>
<td width="414">±0.1°C</td>
</tr>
<tr>
<td width="258">Temperature Range</td>
<td width="414">4°C to 99°C</td>
</tr>
<tr>
<td width="258">Peltier Element/Block</td>
<td width="414">4</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Heated Lid</strong></td>
</tr>
<tr>
<td width="258">Selectable Heated Lid Temperature</td>
<td width="414">100°C to 115°C</td>
</tr>
<tr>
<td width="258">Heated Lid – Enable/Disable</td>
<td width="414">Yes</td>
</tr>
<tr>
<td colspan="2" width="672"><strong>Programming</strong></td>
</tr>
<tr>
<td width="258">No. of Programs</td>
<td width="414">80</td>
</tr>
<tr>
<td width="258">Programming Display</td>
<td width="414">4-line alphanumeric</td>
</tr>
<tr>
<td width="258">Auto Restart on Power Failure</td>
<td width="414">Yes</td>
</tr>
<tr>
<td width="258">Dimensions (WxLxH)</td>
<td width="414">170 x 330 x 190mm (6.7 x 13 x 7.5”)</td>
</tr>
<tr>
<td width="258">Voltage</td>
<td width="414">100/115/230V 50-60Hz</td>
</tr>
<tr>
<td width="258">Power</td>
<td width="414">230W</td>
</tr>
<tr>
<td width="258">Shipping Weight</td>
<td width="414">8 kg (17.6 lbs)</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2460/tc-3000-thermal-cycler/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Quantica® Real-Time PCR Machine</title>
		<link>http://www.idealscientific.com/2441/quantica-real-time-pcr-machine/</link>
		<comments>http://www.idealscientific.com/2441/quantica-real-time-pcr-machine/#comments</comments>
		<pubDate>Thu, 03 May 2012 19:20:18 +0000</pubDate>
		<dc:creator>brenda</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2441</guid>
		<description><![CDATA[Quantica® has been designed with the advantage of having an open architecture and chemistry format that allows the end user &#8230; <a class="read-more" href="http://www.idealscientific.com/2441/quantica-real-time-pcr-machine/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>Quantica® has been designed with the advantage of having an open architecture and chemistry format that allows the end user full flexibility of the methods and research they wish to pursue.</p>
<p><strong>Quansoft® Software and Reporting:  </strong>Accompanying Quantica® is our easy-to-use, flexible software Quansoft®, which gives you the freedom to see your raw data, choose your disposables and choose your own chemistries!</p>
<p>Here&#8217;s just some of the things you can finally do with Quansoft®:</p>
<ul>
<li>ability to create, modify and save files using Quansoft® while a program is running on the unit</li>
<li>ability to run without initially defining your plate layout and analysis criteria &#8211; just pop a prepared plate in &amp; run a program</li>
<li>ability to export unprocessed, raw data</li>
<li>install Quansoft® on multiple PCs without paying a license fee (only a simple registration is required)</li>
<li>ability to change from first order derivative to fit points in results analysis</li>
</ul>
<p><strong>Features</strong></p>
<ul>
<li>Solid state white light source and PMT (photomultiplier tube) detector gives an impressive excitation range of 470nm to 650nm and a detection range of 500nm to 710nm.</li>
<li>Multiplex &#8211; multiple wavelengths are detectable per sample using up to four paired excitation and emission filters housed in individual cartridge systems.</li>
<li>Wide dynamic range &#8211; up to at least 9 orders of magnitude from starting copy number and high sensitivity, detecting down to 1nM fluorescein and single copy templates, depending upon the assay.</li>
</ul>
<p><strong>Heated Lid</strong></p>
<p>The flexible optical heated lid system is designed to minimize loss of sample and prevent sample condensation. Temperature controlled, it allows further method optimization where pre-incubation stages may be required (e.g. in reverse transcription techniques) or where changes in the heated lid characteristics are needed during the different stages of a program run.</p>
<p><strong>Warranty: </strong>2 years</p>
<p>Made in the USA.</p>
<table width="100%" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="248"><strong>Item No.</strong></td>
<td valign="top" width="424"><strong>Description</strong></td>
</tr>
<tr>
<td valign="top" width="248"><strong>IS18385</strong></td>
<td valign="top" width="424">Quantica® Real-Time PCR Machine</td>
</tr>
<tr>
<td valign="top" width="248"><strong><span style="color: #000000; font-family: Verdana;"> </span></strong></td>
<td valign="top" width="424"><strong>Filters</strong></td>
</tr>
<tr>
<td valign="top" width="248"><strong>IS18386</strong></td>
<td valign="top" width="424">FAM Multiplex, 460nm excitation wavelength, 500nm emission wavelength</td>
</tr>
<tr>
<td valign="top" width="248"><strong>IS18387</strong></td>
<td valign="top" width="424">Green, FAM|SYSBR®, 485nm excitation wavelength, 520nm emission wavelength</td>
</tr>
<tr>
<td valign="top" width="248"><strong>IS18388</strong></td>
<td valign="top" width="424">Yellow, HEX, 530nm excitation wavelength, 560nm emission wavelength</td>
</tr>
<tr>
<td valign="top" width="248"><strong>IS18389</strong></td>
<td valign="top" width="424">Red, ROX, 580nm excitation wavelength, 615nm emission wavelength</td>
</tr>
<tr>
<td valign="top" width="248"><strong>IS18390</strong></td>
<td valign="top" width="424">Blue, Cy5, 640nm excitation wavelength, 685nm emission wavelength</td>
</tr>
<tr>
<td colspan="2" valign="top" width="672">*Please note IS18386 is not included with the unit.</td>
</tr>
<tr>
<td colspan="2" valign="top" width="672"><strong><span style="color: #000000; font-family: Verdana;"> </span></strong></td>
</tr>
<tr>
<td colspan="2" valign="top" width="672"><strong>Thermal Cycler</strong></td>
</tr>
<tr>
<td valign="top" width="248">Block Format</td>
<td valign="top" width="424">96 x 0.2mL well</td>
</tr>
<tr>
<td valign="top" width="248">Block Specification</td>
<td valign="top" width="424">8 x Peltier block employing quad-circuit technology to enhance performance</td>
</tr>
<tr>
<td valign="top" width="248">Block Uniformity at 50°C</td>
<td valign="top" width="424">Better than 0.3°C</td>
</tr>
<tr>
<td valign="top" width="248">Maximum Ramp Rate</td>
<td valign="top" width="424">Up to 2.2°C</td>
</tr>
<tr>
<td valign="top" width="248">Temperature Range</td>
<td valign="top" width="424">4°C to 98°C</td>
</tr>
<tr>
<td valign="top" width="248">Sample Volume</td>
<td valign="top" width="424">15 to 50µl</td>
</tr>
<tr>
<td valign="top" width="248">Heated Lid</td>
<td valign="top" width="424">Adjustable between 100°C and 115°C in 1°C increments, or off</td>
</tr>
<tr>
<td valign="top" width="248">Maximum Sample Evaporation</td>
<td valign="top" width="424">Less than 15% volume loss from any well using the plate sealing recommended by Techne</td>
</tr>
<tr>
<td valign="top" width="248">PC Connectivity</td>
<td valign="top" width="424">USB, OS Win XP SP3 or higher and Win 7 (one unit per PC)</td>
</tr>
<tr>
<td valign="top" width="248">Plate Format</td>
<td valign="top" width="424">Low profile 96-well plate (skirted or non-skirted)</td>
</tr>
<tr>
<td colspan="2" valign="top" width="672"><strong>Optical Detection System</strong></td>
</tr>
<tr>
<td valign="top" width="248">Excitation Source</td>
<td valign="top" width="424">Solid state white light source</td>
</tr>
<tr>
<td valign="top" width="248">Detector</td>
<td valign="top" width="424">Photon counting photomultiplier tube</td>
</tr>
<tr>
<td valign="top" width="248">Multiplex Dye Detection</td>
<td valign="top" width="424">Up to 4 dyes per reaction tube</td>
</tr>
<tr>
<td valign="top" width="248">User Selected Filters</td>
<td valign="top" width="424">Max. of 4 paired excitation/emission filter cartridge systems suitable with currently used dyes*</td>
</tr>
<tr>
<td valign="top" width="248">Fluorescence Excitation Range</td>
<td valign="top" width="424">470nm – 650nm (standard filters are centered at 485, 530, 580 and 640nm)</td>
</tr>
<tr>
<td valign="top" width="248">Fluorescence Detection Range</td>
<td valign="top" width="424">500nm – 710nm (standard filters are centered at 520, 560, 615, 685nm)</td>
</tr>
<tr>
<td valign="top" width="248">Dynamic Range</td>
<td valign="top" width="424">At least 9 orders of magnitude of target DNA concentration</td>
</tr>
<tr>
<td valign="top" width="248">Sensitivity (detection threshold)</td>
<td valign="top" width="424">1nM fluorescein in a 20µl sample</td>
</tr>
<tr>
<td valign="top" width="248">Resolution</td>
<td valign="top" width="424">1.5 fold difference in target DNA concentration</td>
</tr>
<tr>
<td valign="top" width="248">Weight</td>
<td valign="top" width="424">55 lbs</td>
</tr>
<tr>
<td valign="top" width="248">Dimensions (WxDxH)</td>
<td valign="top" width="424">16 x 20 x 21”</td>
</tr>
<tr>
<td valign="top" width="248">Input Power</td>
<td valign="top" width="424">715W</td>
</tr>
<tr>
<td valign="top" width="248">Power Supply</td>
<td valign="top" width="424">100V to 230V, 50/60Hz</td>
</tr>
<tr>
<td colspan="2" valign="top" width="672">*Custom filter cartridge systems available upon request.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2441/quantica-real-time-pcr-machine/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Jenway 3505 Bench pH Meter</title>
		<link>http://www.idealscientific.com/2430/jenway-3505-bench-ph-meter/</link>
		<comments>http://www.idealscientific.com/2430/jenway-3505-bench-ph-meter/#comments</comments>
		<pubDate>Wed, 18 Apr 2012 16:30:33 +0000</pubDate>
		<dc:creator>brenda</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2430</guid>
		<description><![CDATA[The 3505 is a simple to use laboratory pH, mV and temperature meter for use in general purpose and educational &#8230; <a class="read-more" href="http://www.idealscientific.com/2430/jenway-3505-bench-ph-meter/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>The 3505 is a simple to use laboratory pH, mV and temperature meter for use in general purpose and educational applications. It utilises rotary controls for mode selection and pH calibration. A novel design feature ensures that inadvertent movement of the calibration controls has no effect during sample measurement. The large display ensures that during demonstrations and when used by groups, all can easily see the clear LCD readout.</p>
<ul>
<li>General purpose education laboratory pH meter</li>
<li>Intuitive operation via rotary controls</li>
<li>pH, temperature and mV mode for redox and electrode diagnosis</li>
<li>Calibration controls locked during measurement</li>
<li>Manual or automatic temperature compensation</li>
<li>Large display</li>
<li>Battery or mains operated</li>
</ul>
<p>Ordering Information:  3505 pH meter supplied with epoxy combination pH electrode (924 001), electrode stand and holder, ATC probe (027 500), BNC shorting plug, buffer sachets and battery.</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="319"><strong><span style="color: #000000;">Item No.</span></strong></td>
<td valign="top" width="319"><strong><span style="color: #000000;">IS17294</span></strong></td>
</tr>
<tr>
<td colspan="2" valign="top" width="638"><strong><span style="color: #000000;">pH</span></strong></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Range</span></td>
<td valign="top" width="319"><span style="color: #000000;">-2.00 to +16.00</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Resolution</span></td>
<td valign="top" width="319"><span style="color: #000000;">0.01</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Accuracy</span></td>
<td valign="top" width="319"><span style="color: #000000;">±0.02</span></td>
</tr>
<tr>
<td colspan="2" valign="top" width="638"><strong><span style="color: #000000;">mV</span></strong></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Range</span></td>
<td valign="top" width="319"><span style="color: #000000;">±1999mV</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Resolution</span></td>
<td valign="top" width="319"><span style="color: #000000;">1mV</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Accuracy</span></td>
<td valign="top" width="319"><span style="color: #000000;">±1mV</span></td>
</tr>
<tr>
<td colspan="2" valign="top" width="638"><strong><span style="color: #000000;">Temperature</span></strong></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Range</span></td>
<td valign="top" width="319"><span style="color: #000000;">-10 to +105°C</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Resolution</span></td>
<td valign="top" width="319"><span style="color: #000000;">0.1°C</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Accuracy</span></td>
<td valign="top" width="319"><span style="color: #000000;">±0.5°C</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">ATC Range</span></td>
<td valign="top" width="319"><span style="color: #000000;">0 to 100°C</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Connector</span></td>
<td valign="top" width="319"><span style="color: #000000;">BNC</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Power</span></td>
<td valign="top" width="319"><span style="color: #000000;">9V PP3 battery as standard or optional 9V power supply</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Size (LxWxD)</span></td>
<td valign="top" width="319"><span style="color: #000000;">210 x 250 x 55 mm</span></td>
</tr>
<tr>
<td valign="top" width="319"><span style="color: #000000;">Weight</span></td>
<td valign="top" width="319"><span style="color: #000000;">850g</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2430/jenway-3505-bench-ph-meter/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Electrothermal Paraffin Section Mounting Bath</title>
		<link>http://www.idealscientific.com/2420/mh8516-paraffin-mounting-bath/</link>
		<comments>http://www.idealscientific.com/2420/mh8516-paraffin-mounting-bath/#comments</comments>
		<pubDate>Tue, 10 Apr 2012 17:03:42 +0000</pubDate>
		<dc:creator>brenda</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2420</guid>
		<description><![CDATA[The Paraffin Section Mounting Bath is designed to assist with the handling of paraffin wax samples in histology and pathology &#8230; <a class="read-more" href="http://www.idealscientific.com/2420/mh8516-paraffin-mounting-bath/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>The Paraffin Section Mounting Bath is designed to assist with the handling of paraffin wax samples in histology and pathology laboratories. It is essentially a hot distilled water floating out bath that allows for the meticulous manipulation and location of paraffin wax sections onto glass slides.</p>
<p>A white neon light indicates &#8220;Power On&#8221; and an amber neon light indicates &#8220;Heater On&#8221;. The required temperature is selected using the heater dial and a nominal temperature of 70°C is typically achieved with 2 litres of water within 120 minutes.</p>
<p>Accurate water temperature is then maintained through an energy regulator which supplies power to a silicone rubber mat in controlled timed pulses. Over-heating of the bath is prevented by a thermal fuse within the heater mat which automatically cuts out at too high a temperature.</p>
<ul>
<li>
<div align="LEFT">PTFE black interior and powder-coated white aluminum exterior</div>
</li>
<li>
<div align="LEFT">Virtually maintenance-free and extremely easy to clean</div>
</li>
<li>
<div align="LEFT">Excess or damaged sections may be simply removed by skimming a filter paper over the water surface</div>
</li>
<li>
<div align="LEFT">70°C nominal temperature for 2 litres of water, attained within 120 minutes</div>
</li>
</ul>
<p align="LEFT">Warranty:  One year parts &amp; labour</p>
<table width="100%" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="316"><strong>Item No.</strong></td>
<td width="356"><strong>IS17156</strong></td>
</tr>
<tr>
<td>Capacity</td>
<td width="356">2.25 litres</td>
</tr>
<tr>
<td>Temperature</td>
<td width="356">Ambient +5°C to 75°C using arbitrary 1 to 10 scale</td>
</tr>
<tr>
<td>Overall Dimensions (WxDxH)</td>
<td width="356">33 x 33 x 14 cm (13 x 13 x 5”)</td>
</tr>
<tr>
<td>Chamber Dimensions (WxDxH)</td>
<td width="356">22 x 22 x 7 cm (8.7 x 8.7 x 3”)</td>
</tr>
<tr>
<td>Weight</td>
<td width="356">2.7 kg (6 lbs)</td>
</tr>
<tr>
<td rowspan="2">Electrical</td>
<td width="356">IS17156: 115V, 50/60Hz, 240W</td>
</tr>
<tr>
<td width="356">IS17155: 230V, 50/60Hz, 240W<strong></strong></td>
</tr>
<tr>
<td>Optional Accessories</td>
<td width="356">Item No. IS17158:  Lid for Paraffin Section Mounting Bath</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2420/mh8516-paraffin-mounting-bath/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1701 Kirchhoff-Bunsen Spectroscope</title>
		<link>http://www.idealscientific.com/2316/1701-spectroscope/</link>
		<comments>http://www.idealscientific.com/2316/1701-spectroscope/#comments</comments>
		<pubDate>Tue, 10 Jan 2012 15:14:57 +0000</pubDate>
		<dc:creator>dan</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2316</guid>
		<description><![CDATA[Easy calibration for most laboratory applications. The 1701 Spectroscope is a Kirchhoff-Bunsen Spectroscope, used for qualitative analysis and measurement of &#8230; <a class="read-more" href="http://www.idealscientific.com/2316/1701-spectroscope/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p><strong>Easy calibration for most laboratory applications.</strong></p>
<p>The 1701 Spectroscope is a Kirchhoff-Bunsen Spectroscope, used for qualitative analysis and measurement of emission and absorption spectra. It can be calibrated easily, and both the observation tube and ocular is moveable. Accessories include scale illumination, wavelength scale, spare prism and lamp. The specifications:</p>
<p>•Observation tube: moveable, with lock-screw moveable ocular</p>
<p>•Objective: 18 mm / 160 mm</p>
<p>•Slit tube: fixed, with variable slit objective: 18 mm / 160 mm</p>
<p>•Scale tube: fixed, with scale of 200 divisions ocular: 18 mm / 90 mm</p>
<p>•Flint prism: 60 °, dispersion C-F=2 °, base length 20 mm, height 30 mm</p>
<p><strong> </strong></p>
<p>&nbsp;</p>
<h3><strong>Warranty</strong></h3>
<ul>
<li>Two year warranty + one year warranty extension</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2316/1701-spectroscope/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>1836 Laboratory Spectrometer-Goniometer</title>
		<link>http://www.idealscientific.com/2313/1836-laboratory-spectrometer/</link>
		<comments>http://www.idealscientific.com/2313/1836-laboratory-spectrometer/#comments</comments>
		<pubDate>Tue, 10 Jan 2012 14:46:33 +0000</pubDate>
		<dc:creator>dan</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.idealscientific.com/?p=2313</guid>
		<description><![CDATA[Exact measurement of optical data on prisms. We offer the Krüss model 1836 Spectrometer-Goniometer, for the exact measurement of optical &#8230; <a class="read-more" href="http://www.idealscientific.com/2313/1836-laboratory-spectrometer/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p><strong>Exact measurement of optical data on prisms.</strong></p>
<p>We offer the Krüss model 1836 Spectrometer-Goniometer, for the exact measurement of optical data on prisms. It can also be used as a spectroscope, for qualitative examination and measurement of emission and absorption spectra. The observation tube has combined coarse and fine drives, infinitely variable, cross-hairs, eyepiece vernier accuracy, plus 1 minute of arc objective: 18 mm/160 mm. The Prism offers Flint glass (60deg) with a dispersion angle C-F=2deg. The scale tube is a symmetric precision slit of hardened steel. Accessories include prism, Rowland grating and holder, scale illumination, lamp, ocular and spectra sheet.</p>
<p><strong> </strong></p>
<p>&nbsp;</p>
<h3><strong>Warranty</strong></h3>
<ul>
<li>Two year warranty + one year warranty extension</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.idealscientific.com/2313/1836-laboratory-spectrometer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

